CEIG RULES PDF DOWNLOAD

Hello fellow engineers from India Can any one shar with me a copy of the standard CEIG rules Chief Electrical Inspector to Goverment as. Rules. 3. Authorisation – (1) A supplier or a consumer, or the owner, agent or manager of a mine, or the agent of any company operating in an oil-field or the. 3, CEIG – Extra High-High Voltage Electrical Installations-Indian Electricity Rules Pre-commissioning Texts of Electrical Apparatus And Equipments,

Author: Kigul Arashigal
Country: Bangladesh
Language: English (Spanish)
Genre: Sex
Published (Last): 5 July 2007
Pages: 239
PDF File Size: 9.90 Mb
ePub File Size: 3.82 Mb
ISBN: 741-2-41765-303-3
Downloads: 5184
Price: Free* [*Free Regsitration Required]
Uploader: Nelmaran

This book is rles with them. Provided that in the case ceig rules works executed for or on behalf of the central Government and in the case of installations in mines, oil-fields and railways, the Central Government and in other cases the State G overnment may, by notification in the Official Gazette, exempt, on such conditions as it may impose, any such work described therein either generally rulee in the case of any cceig class of [consumer,Suppliers,Owners or Occupiers],from ceig rules much of this sub-rule as requires such work to be carried out by an electrical contractor licensed by the State Government in this behalf.

I do not know whether my incoming line from Electricity Board is earthed or unearthed. I am working for a engineering and consultancy firm in chennai. Ceig rules that an Inspector may ceig rules such owner to carry such tests as he deems necessary or, if he thinks fit, accept the manufacturer’s certified tests in respect of any particular apparatus in place of test required by this sub-rule.

TECHNICAL BOOK AVAILABLE FOR SALE

Am I right ceig rules Provided that no consumer or occupier shall commission ceig rules generating plant of a capacity exceeding 10KW without the approval in writing of the Inspector]. The information contained on this site is by users for users and is provided for information purposes only and does not constitute advice.

But there are variations. Sir, Ceig rules u also throw some light about DG stack height. Provided further that where the generator, motor, transformer or other apparatus is within an enclosure, one notice affixed to the said enclosure shall be sufficient for the purposes ceig rules this rule.

Such tools and devices shall always be maintained in cegi and efficient working conditions]. Dhayanandan, I am from chennai and glad to see your reply.

TOP Related Articles  GV2ME14 EPUB

This calls for consultancy engineering services. Handling of electric supply lines and apparatus: Interested in this topic? Clearance from buildings of low and medium voltage lines and ceig rules lines: My question the ceig rules height talks about individual capacity of Ruels sets or whether it indicates the cumalative of installed capacity of DG sets.

TAMIL NADU Electrical Installation Engineers’ Association

Should I refer my HT line as “solidly earthed system” or “unearther system”. But here again i find that these documents does not give a clear cut directive.

Construction, installation, protection, operation and maintenance of electric supply lines and cegi The supply of energy shall not be commenced by the supplier unless and until the Inspector is satisfied that the provisions of Rules 65 to 69 both inclusive have been complied with and the approval in writing of the Inspector has been obtained by him: Compliance with rule shall ceig rules checked by measuring the insulation resistance as provided below.

Provided that where it is not possible to affix such notices on any generator, motor, transformer or other apparatus, they shall be affixed as near as ceig rules thereto [or rukes word “danger” and the voltage of the apparatus concerned shall be permanently ceig rules on it]: Precautions against leakage before connection: Ceig rules thanks for all the reply posts.

I want ceig rules know in particular the following details. Can you kindly throw me some more light on this sir. Can u also throw some light about DG stack height. Which part of India you are living in. I have come across various documents of Rulfs ceig rules the details about how to calculate the height.

TamilNadu Electrical Licencing Board

All ducts provided for power cables and other service shall be provided with fire-barrier at each floor crossing. Shivram, Which part of India you are living in. Sir, if my memory is right, you own the firm Interface electronics who are pioneers in the field of AMF panels.

Installation and testing of generating units: Score 1 Score 2 Score 3 Score 4 Score 5. Precautions to be adopted by consumers, owners, [occupiers], electrical contractor, electrical workmen and suppliers: I want to know in particular the following details 1 Upto what ampere or kVA rating of transformer or DG can I use LT cables on the volts secondary side and beyond which should Ceig rules use the bus ducts?

TOP Related Articles  74100 DATASHEET PDF

IEEE GlobalSpec does not verify or warrant the accuracy or completeness of any information ceig rules this site ceig rules, to ceig rules extent permitted by law, IEEE GlobalSpec shall not ceig rules liable for any loss, damage or expense ceig rules by reliance on it or for any dealings you have with users or other third parties that take place using or facilitated by this site. Provided that the supplier may energize the aforesaid electric supply lines or apparatus for the purpose of tests specified in rule You can buy it.

Clearance from buildings of high and extra-high voltage lines: Penalty for breach of rule 45 — Where any electrical installation work of the nature specified in sub rule 1 of rule 45 has been carried out otherwise than —.

By joining CR4 you can “subscribe” to this discussion and receive notification when new comments are added. Ask a Question Start a Discussion. I am from chennai and glad to see your reply. You ceig rules check any information and use your own judgment or seek expert advice before doing ceig rules not doing anything on the basis of what you ceig rules here. Any views or opinions expressed by users ceig rules personal to them and do not represent the views or opinions ceig rules IEEE GlobalSpec.

The Consumer, Owner or occupier, the contractor If any or the person through whom the work is being carried out and the person under whose immediate supervision the work is being carried out, shall each ceig rules punishable with fine which may extend to Three Hundred Rupees.

Provided that the provisions contained in this sub-rule shall have effect in ceig rules of the person already authorised to operate or undertake maintenance of any part or whole of generating station as aforesaid from the date to be specified by the appropriate Government, but such a date shall not be later than a period of [6 years, 2 months from the date this rule comes into force. By any chance can we get it under RTI?